Learn how the FullForce FRC Calculator works, understand the calculation methodology, and get technical support for your fiber reinforcement projects.
Overview
The FullForce FRC Calculator determines the required dosage rate of FiberForce synthetic macrofibers as a replacement for traditional steel reinforcement (rebar or welded wire reinforcement) in concrete slabs.
Per ACI 360R-10 Section 3.2.2: Synthetic macrofibers such as FiberForce are recognized and considered a complete replacement of WWR in concrete members that are fully supported for crack-width control due to shrinkage and temperature restraint.
Calculation Methodology
1Yield Strength (fy)
Determined by reinforcement type:
- • Rebar: Default 60,000 psi
- • WWR: Default 65,000 psi
2Area of Steel (As)
Calculated based on reinforcement size and spacing:
Rebar: As = (12" / Spacing) × Abar
WWR: As = (W-number / 100) × (12" / Spacing)
3Reinforcement Ratio (ρ)
Ratio of steel area to concrete section:
ρ = As / (12" × h)
where h = concrete thickness
4Steel Tension Strength (σsteel)
Based on yield stress and reinforcement ratio:
σsteel = ρ × (0.6 × fy)
5FRC Equivalent Strength (fe3)
Convert steel stress to required FRC residual strength:
fe3 = σsteel / 0.37
6Required Fiber Dosage
Determined using fiber-specific trendline data:
Dosage = (fe3 - intercept) / slope
Subject to min/max limits per fiber type
FiberForce Products
FiberForce 750
High-performance synthetic macrofiber for structural applications.
Dosage: 3.0 - 12.0 lb/cy
FiberForce 650
Versatile macrofiber for general concrete reinforcement.
Dosage: 3.0 - 12.0 lb/cy
FiberForce T1-60
Engineered fiber for temperature and shrinkage control.
Dosage: 3.0 - 7.5 lb/cy
Industry Standards Compliance
ACI 360R-10 Section 3.2.2
Design of Slabs-on-Ground — Slabs Reinforced for Crack-Width Control
ACI 544.4R-18 Eq. 4.5a
Guide for Design with Fiber-Reinforced Concrete
ASTM C1609/C1609M
Standard Test Method for Flexural Performance of FRC
ANSI/SDI C-2017
Standard for Composite Steel Floor Deck-Slabs — Temperature reinforcement alternative
Contact & Support
Phone
205.620.9889
info@fullforcesolutions.us
Address
ABC Polymer Industries, LLC
Birmingham, Alabama
Ready to Calculate?
Use our FRC Calculator to determine the optimal fiber dosage for your project.
Open CalculatorInput Reference
Concrete Thickness
Slab thickness in inches
Compressive Strength
f'c in psi (optional)
Rebar Sizes
#3, #4, #5 (larger sizes: contact rep)
WWR Sizes
W1.4, W1.7, W2.1, W2.9, W4.0